Powerware 9305 UPS Technical Specs

Powerware 9305
Rating  7.5 kVA  10 kVA  15 kVA
Capacity (VA/watts)  7.5 / 5.25  10 / 7  15 / 10.5
Dimensions WxDxH (mm)  400x750x700 
Weight (kg)  180  220
Input connection  Hardwired
Output connection  Hardwired
Typical runtime  Full load 7 min 7 min 7 min
Half load 20 min 20 min 20 min
Rating  20 kVA  30 kVA  40 kVA
Dimensions WxDxH (mm)  520x788x1530
Weight (kg)  400 490 230
Input connection  Hardwired
Output connection  Hardwired
Typical runtime  Full load 12 min 7 min 10 min (ext. bat)
Half load 30 min 18 min 25 min
Rating  50 kVA  60 kVA  80 kVA
Capacity (VA/watts)  50 kVA/35 kW  60 kVA/42 kW  80 kVA / 56 kW
Dimensions WxDxH (mm)  520x788x1530
Weight (kg)  260 260 280
Input connection  Hardwired
Output connection  Hardwired
Typical runtime  Full load 7 min (ext. bat) 10 min (ext. bat) 13 min (ext. bat)
Half load 20 min 28 min 30 min
Operational
Nominal input voltage (Vac)  220/380, 230/400, 240/415 Vac three-phase 
Input voltage range  170/294 to 279/484 Vac (7.5/10/15 kVA);
170/294 to 275/476 Vac (20/30 kVA);
170/294 to 279/484 Vac (40/50 kVA);
180/312 to 279/484 Vac (60 kVA) 
Operating frequency  50/60 Hz (45 to 65 Hz) 
Input power factor  0.96 
Input power factor  10% THDi with input filter 
Nominal output voltage   220/380, 230/400, 240/415 Vac three-phase 
Output voltage regulation ±1% static, 100% unbalanced load accepted;
±5% dynamic at 100% load change, <1 ms recovery time 
Overload capacity  101-110% for 10 min (online);
111-125% for 1 min (online);
126-150% for 30 sec (online);
150-170 % for 5 sec (online);
1000% for one cycle (bypass) 
Efficiency 93-94% with rated non-linear load; 97% with Efficiency Optimizer™
User interface
LCD display Multilingual LCD display showing measurements of performance and alarms (View UPS optional with 7.5/10/15 kVA models) 
LED  UPS On, On battery, On bypass, Alarm(7.5/10/15 kVA models also On line, Overtemperature, Service; additionally 4 LEDs for load bar and overload) 
Standard communication ports   2xRS232 for local support, one with modem support;4xrelay contacts: UPS OK/Alarm, Line failure, Low battery, UPS bypassed;4xprogrammable inputs: Generator on, External bypass, Inverter on/off, Environment alarm; 1xEmergency power off input
Optional  20/30/40/50/60 kVA models: 
Parallel capacity/redundancy systems (max. 4 modules),
External battery cabinets and high capacity charger;
Output transformer; 
Input 10% THD filter;
Remote ViewUPS (multilingual LCD display); 
ConnectUPS-E (SNMP/Web adapter); 
LanQuattro (4xRS232 data manager)
7.5/10/15 kVA models:
Parallel redundancy systems (max 2 modules),
External battery cabinets and high capacity charger,
Output transformer,
Input 10% THD filter,
ViewUPS (multilingual LCD display),
ConnectUPS-E (SNMP/Web adapter),
LanQuattro (4xRS232 data manager)
Environmental
 Operating Temperature 0°C to +40°C 
 Storage Temp -25°C to +40°C
 Altitude < 1000 M
 Audible Noise <45 dB (7.5/10/15 kVA)
<50 dB (20/30 kVA) 
<55 dB (40/50/60 kVA)
Certification
Quality  ISO 9001 
Markings  CE / GOST 
Safety  EN 50091-1-1: 1996; IEC 60950 
EMC  EN 50091-2: 1995