| Voltage | 120 | |||
| Model number: | PW 5110 500 | PW 5110 700 | PW 5110 1000 | PW 5110 1500 |
| Part Numbers | 103004256-5501 | 103004257-5501 | 103004258-5501 | 103004259-5501 |
| Capacity | 500VA / 300W | 700VA / 420W | 1000VA/600W | 1440VA/900W |
| Dimensions (hxwxd) | 10.6x3.4x10.2 in | 10.6x3.4x10.2 in | 10.6x3.4x15.1 in | 10.6x3.4x15.1 in |
| Weight (120/230) | 12.1lb/13.4lb | 15.2lb/16.5lb | 28.0lb/29.1lb | 29.1lb/30.2lb |
| Input Connection | 120V models - 6’ Line cord with 90 deg.5-15P / 230V models IEC C14 inlet, 1.8 meter line patch cord IEC to IEC | |||
| Output Connection |
8 Outlets (4 Battery Backup & Surge Protection; 4 Surge
Protection only) 120V models - 5-15R, 230V models - IEC C13 |
|||
| Voltage | 230 | |||
| Model number: | PW 5110 500i | PW 5110 700i | PW 5110 1000i | PW 5110 1500i |
| Part Numbers | 103004261-5501 | 103004262-5501 | 103004263-5501 | 103004264-5501 |
| Capacity | 500VA/300W | 700VA/420W | 1000VA/600W | 1440VA/900W |
| Dimensions (hxwxd) | 10.6x3.4x10.2 in | 10.6x3.4x10.2 in | 10.6x3.4x15.1 in | 10.6x3.4x15.1 in |
| Weight (120/230) | 12.1lb/13.4lb | 15.2lb/16.5lb | 28.0lb/29.1lb | 29.1lb/30.2lb |
| Input Connection | 120V models - 6’ Line cord with 90 deg.5-15P / 230V models IEC C14 inlet, 1.8 meter line patch cord IEC to IEC | |||
| Output Connection |
8 Outlets (4 Battery Backup & Surge Protection; 4 Surge
Protection only) 120V models - 5-15R, 230V models - IEC C13 |
|||
| Operation | ||||
| Input Voltage Range | 120V models ~ 0–160Vac 230V models ~ 0-300Vac | |||
| Output Voltage Range | Nominal -10% to +8% | |||
| On Battery Output Voltage | 115Vac +10% to -12%, 230Vac + 10% to -12% | |||
| Frequency | 50/60 Hz auto sensing | |||
| Lighting / Surge Protection | 120v models 320 joules; 230v models 476 joules | |||
| Safety | UL 1778, Designed to meet UL497A, CAN/CSAOC22.2 No107.1/IEC 6240-1-1: CE low voltage directive | |||
| EMI | 120V models ~ FCC Class B 230V models ~ IEC 62040-2, EN55022: Class B: CE EMC directive | |||
| Transfer Time to Battery/AC | 2-6 msec. typical | |||
| Battery Type | Sealed, maintenance free lead-acid battery | |||
| Typical Backup Time | 3 - 4 minutes at full rated load | |||
| Internet / Phone / Fax Protection | 120V - RJ11/RJ45 230V models - RJ11 | |||
| Short Circuit Protection | Circuit Breaker | |||
| Communication Port | USB | |||
| Environmental | ||||
| Operation Temperature | 0°C ~ 40°C | |||
| Operation Relative Humidity | 0-95%non-condensing | |||
| Storage Temperature | -15°C ~ 50°C | |||
| Software | ||||
| Powerware LanSafe Software is included free of charge. | ||||
Powerware 5110 Run Times for Typical Applications in Minutes
| Load (VA) | 50W | 100W | 150W | 200W | 250W | 350W | 400W | 500W | 600W | 700W | 800W | 900W |
| 500 | 43 | 17 | 11 | 6 | 4 | - | - | - | - | - | - | - |
| 700 | 53 | 30 | 14 | 9 | 7 | 4 | 3 | - | - | - | - | - |
| 1000 | X | 64 | X | 28 | X | X | 12 | 8 | 5 | - | - | - |
| 1500 | X | 74 | X | 35 | X | X | 14 | 10 | 7 | 6 | 5 | 4 |