Powerware 9120 UPS Technical Specs

Model Selection Guide
Optional EBMs
Battery Runtimes
Available Options 
Electrical Input
Nominal Voltage For user-selectable voltages see Model Selection Guide
Input Voltage Range 700-3000VA I
Input Voltage Range 6000VA
120/140/160-276 Vac (at 33%/66%/100% Load)
120/140/160/184-276 Vac (at 25%50%/76%/100% Load)
Input Power Factor >.95%
Operating Frequency 50/60 Hz, Auto-sensing
Frequency Range 45 - 65 Hz
Input Protection Fuse or circuit breaker
Electrical Output
On Utility Voltage Regulation +/-2% of nominal
On Battery Voltage Regulation +/-3% of nominal
Nominal Output Voltage Same as selected input voltage
Output Voltage Waveform Sine Wave
Output Voltage Distortion <3%THD
Output protection Electronic overload sensing,and circuit breaker protection
Efficiency Online Mode:>86% 700VA; >88% 100-3000VA; >90% 6000VA
Hi-Efficiency Mode:>90%
Battery
Internal Battery type Sealed, lead-acid; maintenance free
EBM Battery Type Sealed, lead-acid; maintenance free
On Battery Runtime See Battery Runtimes
Battery Replacement Hot-swappable internal and external batteries
Recharge Time <4 hours to 90%capacity
Start-On-Battery Allows start of UPS without utility input
Communications
User Interface LCD status screen
Audible Alarms UPS alarm conditions,including:
On-Battery,Low Battery,Overload, UPS Fault
Network transient Protector In and out jack for all models.
UL497A tested
REPO Port Meets NEC code 645-11 intent and UL requirements
Communications One RS232 Serial Port;One Communications Slot; One USB Port
Communications cable 6-foot communications cable included
Power Management Software  Powerware Software Suite CD
General
Topology True online, double-conversion
Diagnostics Full system self-test on power up
UPS Bypass Automatic on Overload or UPS failure <4ms
Transfer Time to battery 0 ms
Dimensions and Weights See Model Selection Guide
Overload Capacity  125% for 10 minutes before transfer to bypass;
150% for 10 seconds before transfer to bypass
Environmental and Safety
Safety Certifications CE marked,EN 50091-1-1 and IEC 60950
EMI Compliance FCC Part 15, Class B (700-1500), Class A (2000-3000) 230 V, 
EN 50091-2 Class B (700-1500), Class A (2000-3000)
Operating Temperature 0 to 40 C (32 to 104 F)
Storage Temperature -15 to 50 C (5 to 122 F)
Storage Temperature 0o to 25o C (32o to 77o F)
Relative Humidity 0%to 95%non-condensing
Immunity EEE C62.41,
IEC 61000-4 -2, -3, -4, -5
Network Transient Protector UL497A
Audible Noise at 1 meter 700-1000 VA: <45dB;1500 VA <50dB; 2000-3000 <52dB
Altitude  3000m (10,000 ft) without deteriorating
Note: Due to continuing product improvement programs, specifications are subject to change without notice.

Go to top


Model Selection Guide

Model
Number
Power Out
(VA/Watt)
Input/
Output
Voltage (Vac)
Frequency
(Hz)2
Input
Connection3
Output
Receptacles4
Dimensions
(HxWxD)
in/mm
Weight
(lb/kg)
120 Vac Models1
PW9120 700 700/490 120 50/60 5-15P (4) 5-15R 240 x 155 x 410 13.2
PW9120 1000 1000/700 120 50/60 5-15P (4) 5-15R,
(2) 5-20R
240 x 155 x 410 15
PW9120 1500 1500/1050 120 50/60 5-15P (4) 5-15R,
(2) 5-20R
275 x 170 x 445 21.1
PW9120 2000 2000/1400 120 50/60 5-20P (6) 5-20R 365 x 215 x 470 37.2
PW9120 3000 3000/2100 120 50/60 L5-30P (4) 5-15R,
(2) 5-20R
(1) L5-30R
365 x 215 x 470 40.5
PW9120 3000h 3000/2100 120 50/60 Hardwired Hardwired 365 x 271 x 470 40.5
208 Vac Models
PW9120 3000 3000/2100 208 50/60 L6-20P (2)L6-15R,
(1)L6-20R,
(1)L6-30R
361 x 215 x 472 40.5
240 Vac Models5
PW9120 700A 700/490 240 50/60 IEC-C14 (4) Aust 10A 243 x 158 x 412 13
PW9120 1000A 1000/700 240 50/60 IEC-C14 (4) Aust 10A 243 x 158 x 412 15
PW9120 1500A 1500/1050 240 50/60 IEC-C14 (4) Aust 10A 275 x 170 x 444 20
PW9120 2000A 2000/1400 240 50/60 IEC-C14 (4) Aust 10A 361 x 217 x 472 37
PW9120 3000A 3000/2100 240 50/60 IEC-C20 (4) Aust 10A 361 x 217 x 472 38
PW9120 6000A 6000/4200 240 50/60 Hard Wired Hard Wired 570 x 280 x 580 91
Optional Extended Battery Modules (EBMs)
PW9120 BATT 700 - - - Standard
Connector
- 9.6 x 6.2 x 16.2/ 15
PW9120 BATT 1000 - - - Standard
Connector
- 240 x 155 x 410 20
PW9120 BATT 1500 - - - Standard
Connector
- 275 x 170 x 445 25
PW9120 BATT 2000 - - - Standard
Connector
- 365 x 215 x 472
50
PW9120 BATT 3000 - - - Standard
Connector
- 365 x 215 x 472
50
PW9120 BATT 6000 - - - Standard
Connector
- 570 x 280 x 580
75
1 Also user-selectable for 100, 110, and 127 Vac.
2 Automatic frequency selection.
3 120V models have 6-ft. attached line cord. 230 V models have 6-ft. detachable line cord.
4 Divided into 2 Load Segments (receptacle groups).
5 Also user-selectable for 220 and 240 Vac

Go to top

Battery Run Times (in minutes full load/half load))

VA Standard
Internal
Battery
1 EBM 2 EBMs 3 EBMs 4 EBMs 5 EBMs
700 6/20 46/96 80/168 - - -
1000 8/21 36/75 62/126 - - -
1500 7/20 32/67 54/112 - - -
2000 14/30 50/100 85/169 78/157 192/403 240/504
 3000 30/65 30/70 50/110 118/236 120/264 148/325
6000 8/23 35/90 65/150 - - -
Up to 2 EBMs can be connected to 700/1000/1500 VA models and up to 5 EBMs can be connected to 2000/3000 VA models.Run time chart provides typical information.Run times are approximate and may vary with equipment,configuration,battery age,temperature,etc.   


Available Options

Order Number Description
Connect UPSBD Connect UPS-BD SNMP/WEB Card
AS400 AS/400 Relay Card
MBS2000SW1 Softwired interlocked Maintenance Bypass Switch 700-2000VA
MBS3000SW1 Softwired interlocked Maintenance Bypass Switch 3000VA
9120MBS1 Hardwired interlocked Maintenance Bypass Switch 3000VA
6000MBS1 Hardwired interlocked Maintenance Bypass Switch 6000VA
Extended Run Time Extended Run time battery packs available – refer factory